Sign In | Join Free | My uabig.com
China China World Technology Medical Equipment Service Group logo
China World Technology Medical Equipment Service Group
China World Technology Medical Equipment Service Group Win-win together!
Verified Supplier

5 Years

Home > Defibrillator Machine Parts >

Mindray BeneHeart D6 Defibrillator Front Casing With Knob And Encoder Hospital Medical Equipment Parts

China World Technology Medical Equipment Service Group
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

Mindray BeneHeart D6 Defibrillator Front Casing With Knob And Encoder Hospital Medical Equipment Parts

  • 1
  • 2
  • 3

Brand Name : Mindray

Model Number : D6

MOQ : 1

Payment Terms : T/T, Western Union,PayPal

Delivery Time : 3-5 working days

Product name : Mindray

Type : D6

Charge time : Less than 3 hours to 90% and less than 4 hours to 100% with equipment power of

Warranty : 90days

Capacity Indicator : 5-segment led indicator for fast battery capacity evaluation

Capacity : Monitoring Mode: 6 hours, Monitoring with a 5-lead ECG,Resp, SpO , CO and NIBP measurements set at an interval of 15 minutes

Wi-Fi : disabled

Line voltage : 100 to 240 V~ (±10%)

Current : 1.8 to 0.8 A

Frequency : 50/60 Hz (±3 Hz)

Input voltage : 12 VDC

Power Consumption : 190 W

Contact Now

Mindray BeneHeart D6 Defibrillator Front Casing with Knob and Encoder

► Brief Introduction

The Mindray BeneHeart D6 Defibrillator's front casing with knob and encoder refers to the physical housing and control components located on the front panel of the device.

This is the outer covering or shell of the defibrillator's front panel. It provides protection to the internal components of the device and houses various control interfaces and indicators.And the knob is a rotary control that can be turned to adjust settings or parameters on the defibrillator. It is often used for tasks such as selecting menu options, adjusting energy levels for defibrillation, or scrolling through information on the display. In the context of the BeneHeart D6 Defibrillator, the encoder is likely used in conjunction with the knob to provide precise control and navigation through menu options or settings.

Together, the front casing with knob and encoder on the Mindray BeneHeart D6 Defibrillator allows healthcare providers to interact with the device, customize settings, and perform necessary actions during defibrillation procedures. These controls are designed to be intuitive and user-friendly, facilitating quick and accurate responses in emergency situations.

► Overview

Mindray BeneHeart D6 Defibrillator Front Casing With Knob And Encoder Hospital Medical Equipment Parts

Area 1:

(1) Alarm lamp

The Alarm lamp flashes in different color and frequency to match the alarm level.

(2) Display screen

(3) AC power indicator

◆ Illuminated: the AC mains is connected.

◆ Off: the AC mains is not connected.

(4) Battery indicator

◆ Yellow: the battery is being charged.

◆ Green: the battery is fully charged or the equipment operates on battery power.

◆ Off: no battery is installed or battery fails.

(5) Service indicator

◆ Flashing: when a failure is detected, or when battery is not installed but AC mains is connected if [No Battery] is configured as [Service Indicator On], or in case of low battery when AC mains is not connected.

◆ Off: the equipment operates properly.

(6) Soft keys

They are corresponding with the soft key labels located immediately above. The labels of the soft keys changes according to the current operating mode.

Area 2:

(1) Alarm Pause button

Press this button to pause, reactivate or switch off the alarms.

(2) Lead Select button

Press this button to select the lead for the first ECG waveform.

(3) 12-Lead ECG button/Event Summary button

◆ 12-Lead ECG button (for equipments configured with 12-lead ECG analysis function): press this button to enter 12-Lead ECG screen.

◆ Event Summary button (for equipments configured without 12-lead ECG analysis function): press this button to record the event summary report.

(4) NIBP button

Press this button to start or stop NIBP measurements.

(5) Speaker

It gives alarm sounds and voice prompts.

(6) Main Menu button

If no menu is displayed on the screen, pressing it will enter the main menu. If there is a menu displayed, pressing it will close that menu.

(7) Navigation knob

◆ Rotate it clockwise or counterclockwise to move the cursor.

◆ Press it to confirm the selection.

(8) Mark Event button

Press it to manually mark specified events. If a menu has been open, pressing this button will close the menu.

(9) Microphone

It is used for voice recording in the AED mode.

Area 3:

(1) Mode Select knob

Rotate this knob to select the operating mode or turn the equipment off.

(2) Energy Select button

In the Manual Defib mode, press this button to select the energy level.

(3) Charge button

Press this button to charge the defibrillator.

(4) Shock button

Press this button to deliver a shock to the patient

► Specification

Main unit: 5.5 kg
Dimensions: 295mm (w) × 218 mm (d) × 279 mm (h)
Line voltage: 100 to 240 V~ (±10%)
Current: 1.8 to 0.8 A
Frequency: 50/60 Hz (±3 Hz)
Input voltage: 12 VDC
Power Consumption: 190 W

Mindray BeneHeart D6 Defibrillator Front Casing With Knob And Encoder Hospital Medical Equipment Parts

Customer satisfaction. Our biggest pursuit! If you have any questions about Mindray BeneHeart D6 Defibrillator Front Casing with Knob and Encoder , please feel free to contact us at any time, we are glad to answer them.


Product Tags:

Knob Defibrillator Front Casing

      

Encoder Defibrillator Front Casing

      

D6 Defibrillator Front Casing

      
Wholesale Mindray BeneHeart D6 Defibrillator Front Casing With Knob And Encoder Hospital Medical Equipment Parts from china suppliers

Mindray BeneHeart D6 Defibrillator Front Casing With Knob And Encoder Hospital Medical Equipment Parts Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: China World Technology Medical Equipment Service Group
*Subject:
*Message:
Characters Remaining: (0/3000)