Sign In | Join Free | My uabig.com |
|
Brand Name : GE
Model Number : RESPONDER 3000 Defibrillator Battery Box
Certification : CE/CB/ROSH
Place of Origin : USA
MOQ : 1
Price : USD
Payment Terms : L/C, D/A, D/P, T/T
Packaging Details : Carton
Brand : GE RESPONDER 3000 Defibrillator
Color : Yellow
Category : Battery Box
Wattanty : 90 Days
Packing weight : 1kg
size : Uniform size
Application area : ICU,medical equipment
Condition : used or new
Estimated Ship Time : 3-5 Business Days
In stock : Enough stock
Material : Battery Box
Used for : 3000 Defibrillator
net weight : 0.25kg
Shape : standard
First, let's take a look at how to remove the battery pack:
1. Set the control dial to OFF to turn off the power, then unplug the power cord from the defibrillator.
2. Use a flat screwdriver to loosen the screw and remove the battery cover.
3. Disconnect the battery cable connector and remove the battery pack from the battery box.
Attention: Do not pull the cable forcefully. Disconnect the cable while holding down the lock.
If the defibrillator is stored without AC power for more than a month, first charge the battery for 48 hours, then remove it from the instrument and place it in a cool and dry place, but it should not be stored below zero degrees Celsius.
Charge stored batteries for at least 24 hours every six months to ensure they do not completely discharge during storage.
When the battery inside the instrument is removed, it should be immediately marked on the instrument. At this time, AC power is required to work.
If the battery cannot be charged for too long, it will cause permanent damage to the battery. Therefore, the battery capacity should be checked at least every six months. Sealed lead-acid batteries should provide a minimum of 2.5 hours of monitoring time. When the minimum 2.5 hours of monitoring time cannot be provided, or when the battery cannot provide a 10 minute "low battery voltage" warning time, the battery needs to be replaced
①Cannot turn on the machine, the AC indicator light is on, and the switch encoder is broken.
② It can only work with batteries and cannot use AC power. The power supply of the whole machine is broken.
③If an error is reported, it is mostly due to a bad power PCA.
④ The self-test cannot be passed, the energy cannot be charged to the preset value, and the power PCA is broken.
⑤Turn on the machine and enter self-test mode, and the panel is short-circuited.
⑥It reports low battery, but the battery is full. Capacity detection circuit problem.
⑦There are many broken motherboards.
⑧Display back panel.
⑨No sound, no display, the motherboard is broken.
Type: | GE RESPONDER 3000 Defibrillator Battery Box |
Warranty period: | 90 Days |
Shipping Date: | 3-5 Working Days |
MODEL: | Battery Box |
Storage temperature: | -20-70°c |
MOQ: | 1 PCS |
COLOR: | Yellow |
Delivery Date: | 3 - 5 Working Days |
Package | Standard export packaging |
The company has been professionally operating various brands of original medical monitoring instruments since 2015. The company has many professional senior engineers and has sufficient ability to undertake various medical equipment maintenance work. Covering motherboards, sensors, probes, modules, connectors, shells, etc. for various medical monitoring equipment.
We default to express delivery by DHL,Fedex,etc.We will contact you as soon as possible when sending express delivery. If you have any questions after receiving the express delivery, please feel free to contact us at any time.
![]() |