Sign In | Join Free | My uabig.com
China China World Technology Medical Equipment Service Group logo
China World Technology Medical Equipment Service Group
China World Technology Medical Equipment Service Group Win-win together!
Verified Supplier

5 Years

Home > Used Ultrasound Transducer >

3C5P Ultrasound Transducer Convex Array Probe for Mindray DC-30 Ultrasound Machine Used in Good

China World Technology Medical Equipment Service Group
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

3C5P Ultrasound Transducer Convex Array Probe for Mindray DC-30 Ultrasound Machine Used in Good

Brand Name : Mindray

Model Number : 3C5P

MOQ : 1pcs

Price : USD

Payment Terms : T/T(wire transfer), Western Union, Paypal

Supply Ability : In stock

Delivery Time : 3-5 working days

Packaging Details : Carton

Product Name : Ultrasound Transducer Convex Array Probe

Brand : Mindray

Model : 3C5P

Type : Convex Array

frequency bandwidth : 2.5/3.5/5.0/H4.6/H6.0 MHz

Applications : adult abdomen, OB/GYN, vascular and pediatric abdominal imaging applications

Use for : Mindray DC-30 Ultrasound Machine

Condition : Used In Good Working

Warranty : 90 days

MOQ : One piece

Delivery method : DHL ,Fedex ,UPS

Power Supply Source : Electric

Payment Method : T/T ,Paypal ,Western Union

Contact Now

3C5P Ultrasound Transducer Convex Array Probe for Mindray DC-30 Ultrasound Machine Used in Good

Brief Description

The Mindray 3C5P Curved Array Transducer has a frequency range of 2.0 MHz to 6.0 MHz and supports obstetrics, gynecology, pediatrics, abdominal, vascular, urology, and veterinary applications.

Specification

Brand name Mindray
Color White
Product name Ultrasound Transducer Convex Array Probe
Condition Used in Good Working
MOQ 1 Piece
Payment Method Paypal,T/T,Western Union
Model 3C5P
Method of Transport Expressage
Delivery 3-5 Working Days
Warranty 90 Days
Type Spare part
Delivery Method DHL ,Fedex ,UPS
Product Category Ultrasound
Power Supply Source Electric
Use Place Hospital ICU Clinic
Product Edge Original,Advanced equipment
Product Characteristic Functional,Durable in use
Packing Carton
Inventory In Stock

3C5P Ultrasound Transducer Convex Array Probe for Mindray DC-30 Ultrasound Machine Used in Good

3C5P Ultrasound Transducer Convex Array Probe for Mindray DC-30 Ultrasound Machine Used in Good

Clean

Refer to the instructions in the manual and follow your hospital's cleaning policies and procedures.

1. Remove the probe from the system.

2. Wear sterile gloves to prevent infection.

3. Clean the transducer with clean water or soapy water to remove any foreign material, or wipe with a soft ethyl urethane sponge. Avoid using a brush as it may damage the transducer.

4. After rinsing, dry the transducer with a sterile cloth or gauze. Do not use heat to dry the transducer.

Immersion Disinfection

1. Wear sterile gloves to prevent infection.

2. Clean the transducer before disinfecting. Mindray recommends using the following solutions to disinfect the probe: For disinfectant concentration, dilution method for disinfection, and precautions for use, please refer to the drug manufacturer's instructions. Do not immerse the probe connector or nearby cables in water or solution.

The probe should be immersed in the disinfectant solution for the minimum time recommended by the manufacturer (for example, the manufacturer recommends a minimum immersion time of 12 minutes for Cidex OPA).

Intraoperative transducers must be sterilized after each examination.

1. Wear sterile gloves to prevent infection.

2. Clean the transducer before sterilization. Mindray recommends using the following solutions to sterilize transducers:

Hydrogen peroxide and peracetic acid based sterilizing solutions

Refer to the chemical manufacturer's instructions for sterilizing solution concentrations, sterilization and dilution methods, and precautions for use.

Do not immerse the transducer connector or nearby cables in water or solutions.

Follow local regulations when selecting and using sterilizing solutions.

3. Flush the transducer with plenty of sterile water (approximately 2 gallons) for at least 1 minute to remove any chemical residue from the transducer. Alternatively, flush the transducer according to the sterilizing solution manufacturer's recommended flushing method.

4. After rinsing the probe, wipe off any water on the probe with a sterile cloth or gauze. Never
Dry the probe using heat.

3C5P Ultrasound Transducer Convex Array Probe for Mindray DC-30 Ultrasound Machine Used in Good

The intraoperative probe can be disinfected at least 217 times (10 hours at a time) using Cidex activated glutaraldehyde solution without compromising safety and performance.
The intraoperative probe can be sterilized at least 135 times (11 hours at a time) using Minncare Cold Sterilizer without compromising safety and performance.

If you're interested in 3C5P Ultrasound Transducer Convex Array Probe for Mindray DC-30 Ultrasound Machine Used in Good ,feel free to contact us .Thank you .


Product Tags:

3C5P Ultrasound Transducer

      

Used Mindray DC-30 Ultrasound Transducer

      

Good Ultrasound Transducer

      
Wholesale 3C5P Ultrasound Transducer Convex Array Probe for Mindray DC-30 Ultrasound Machine Used in Good from china suppliers

3C5P Ultrasound Transducer Convex Array Probe for Mindray DC-30 Ultrasound Machine Used in Good Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: China World Technology Medical Equipment Service Group
*Subject:
*Message:
Characters Remaining: (0/3000)